Customer Support
Search:     Advanced search

Q: Why can I not load my clutch control configuration? Detected module outputs do not match planter sections.

Article ID: 1080
Last updated: 03 Jan, 2014
Revision: 16
Views: 2826


Question
: Why can I not load my clutch control configuration to the run screen? An error message states the number of detected module outputs do not match the number of planter sections. 


Answer
:
When loading the run screen (start field operation wizard), the above error will display if the number of clutches on the planter do not match the number of sections specified in the configuration. To load the run screen:

1.) Check that the high power connection is made to the Clutch Control Module adapter cable on the grey Deutsch 2 pin connectors.

2.) Ensure the configuration has the correct number of sections, pictured below. If not, redo the planter configuration for the correct number of sections (refer to the chart below for assistance.) 


Adapter Family Section Adapter PN # Of Rows # Of Sections
1 Row/Section 4002372 8 6
4001743 12 10
4001746 16 14
4001747 24 22
4001748 36 34
2 Rows/Section 4002039 8 4
4001778 12 6
4001779 16 8
4001780 24 12
4001783 36 18
1 Row/Section (RTK Correction only) 4002759 8 8
4002760 12 12
4002761 16 16
4002762 24 24
4002763 36 36
John Deere RowCommand 4001927-6 12 12
4001923-6 16 16
4001924-6 24 24
4002231-6 36 36
4001926-6 36 36
4001928-6 12/23 (Interplant) 10
4003069-6 12/24 (Interplant) 11
4001951-6 16/31 & 16/32 (Interplant) 14
4001925-6 12,16, 24 6, 8, 12
4003062-6 12/23 (Interplant) 10
4003063-6 12/24 (Interplant) 11
4003066-6 16/31, 16/32 (Interplant) 14
4002993-6 12, 16, 24 6, 8, 12
Ag Leader Swath/STMM 4002784 8 8
4002785 12 12
4002786 16 16
4002787 24 24
4002788 36 36
4003937 12 6
4003938 16 8
4003939 24 12

 3.) Inspect all cabling and connections from the Clutch Control Module(s) to the clutches. It is imperative to have all clutches plugged in for the output detection process.